Mani Diamond Burs - Children'S Densitry / Cd Series
Features:
- Precision cutting with diamond coating.
- Robust stainless steel build.
- Stringent quality control.
- Reduces debris for patient comfort.
- Designed for pediatric dentistry with enhanced accessibility.
- Sterilizable for optimal hygiene.
Technical Specification |
|
---|
- Pack of 5 Burs
Preparation:
- Ensure that the Mani Diamond Burs - CD Series is compatible with your dental handpiece. Check for any compatibility issues or the need for adapters.
- Inspect the burs for any visible damage, wear, or contamination. Discard any damaged or contaminated burs to maintain optimal performance and patient safety.
- Follow strict infection control protocols, including proper sterilization of the burs before each use.
Patient Interaction:
- Establish good communication with the pediatric patient and their guardian. Create a positive and comfortable environment to alleviate anxiety.
- Explain the procedure to the child in an age-appropriate manner, building trust and cooperation.
Positioning and Isolation:
- Position the patient comfortably and stably in the dental chair.
- Utilize isolation techniques such as rubber dam placement to maintain a dry and controlled field during the procedure.
Local Anesthesia:
- Administer local anesthesia as necessary to ensure the child's comfort during the dental procedure. Use techniques appropriate for pediatric patients.
Burs Selection:
- Select the appropriate Mani Diamond Burs from the CD Series based on the specific procedure requirements. Consider the tooth structure and the type of work to be performed (e.g., cavity preparation).
- Ensure that the selected bur is in good condition, free from any defects, and suitable for the intended use.
Handpiece Loading:
- Confirm that the bur is securely and correctly placed in the handpiece.
Procedure Execution:
- Begin the dental procedure with controlled and precise movements, taking care to minimize unnecessary pressure.
- Monitor the cutting efficiency of the bur during the procedure. Make any necessary adjustments to ensure optimal performance.
- Use gentle and continuous motions to avoid heat generation and discomfort for the patient.
- Minimize debris generation by periodically clearing the area with water spray or suction.
Post-Procedure Care:
- After completing the dental procedure, carefully remove the Mani Diamond Bur from the handpiece.
- Follow proper cleaning and sterilization procedures for the burs before their next use.