Operative Modes: Adults And Pediatrics

  • VCV Volume Control (Assisted/Controlled)
  • PCV Pressure Control (Assisted/Controlled)
  • PSV Pressure Support
  • CPAP Continuous Positive Airway Pressure
  • SIMV (VCV) + PSV
  • SIMV (PCV) + PSV
  • MMV + PSV Mandatory Minute Ventilation
  • PSV + Tidal Volume Assured
  • APRV Airway Pressure Release Ventilation
  • PRVC Pressure Regulated Volume Control
  • NIV Non-Invasive Ventilation

Parameter Selection: (according to operative mode and patient category)

  • Tidal Volume: 20-2500 mL
  • Programmable Minute Volume (MMV + PSV): 1.0-50 L/min
  • Resulting Minute Volume: 0.01-130 L/min
  • Inspiratory Time: 0.1-3 seconds (30 seconds in APRV)
  • I:E Ratio: 5:1 – 1:599
  • Respiratory Rate: ADL: 1-100 bpm
  • PED/NEO-INF: 1-150 bpm
  • FiO2 : 21-100%
  • Inspiratory sensitivity:
  • Flow Triggered: 0.2-15 L/min
  • Pressure Triggered: 0.5-20 cmH O below PEEP 2
  • Expiratory sensitivity for PSV: 5%-80% of the initial peak flow, in steps of 5%
  • PEEP/CPAP: 0-50 cmH2O
  • Controlled Pressure (PCV): 2-100 cmH2O
  • Support Pressure (PSV): 0-100 cmH2O
  • Inspiratory Pause (programmable in VCV): 0-2 seconds
  • Inspiratory Flow Waveform (in VCV): Rectangular and Descending Ramp
  • Inspiratory Flow (resultant): 0.2-180 L/min
  • Continuous Flow (NEO-INF): 2-40 L/min
  • Limited Pressure in TCPL (NEO-INF): 3-70 cmH2O
  • Maximum pressure limited (safety limits): up to 120 cmH2O
  • USFDA and CE Approved
  • Warranty and Services provided anywhere in India

Schiller GraphNet Ts Adult, Pediatric Ventilator

In stock
SKU
SBSLR01800
Schiller GraphNet Ts Adult, Pediatric Ventilator is available to buy in increments of 1

Contact us for sales assistance from our Biomedical Engineer.

Prashanth Reddy V | Senior Sales Executive

+91 9063507429

[email protected]

12″ touchscreen displays waveforms & loops simultaneously
Proximal Flow Sensor for neonatal patient category
Advanced modes like PRVC, APRV, MMV+ Pressure Support, PSV+ assured Volume
Non Invasive Ventilation available
Dedicated Neonatal Ventilation modes like TCPL, SIMV+TCPL+PS, N-CPAP
Suction % O2 for suction sequence with variable FiO2
Tidal Volume correction according to BTPS
Endo tracheal tube, altitude and circuit compliance compensation & leak compensation in all modes
Integrated nebulizer
Advanced Lung Mechanism calculation
Auto-PEEP and Trapped Volume, WOBi, Exp. Time Constant, P/V Flex Monitoring, Slow Vital Capacity ( NIF), Pi Max, Physiological Dead Space
Suction % O2 for suction sequence with variable FiO2
Certification: CE 0434 FDA